ISO 9001:2008 Requirement for Control and Monitoring of Measurement Equipment

Chemistry, micro testing, chemical analysis, sampling

Inquiry

I am trying to clearly understand the  ISO 9001:2008 requirement for Control and Monitoring of Measurement Equipment.  My question:

If a measurement equipment like a Karl Fisher Titrator or pH meter which is calibrated by the user with a known standard traceable to an international standard, then does the unit itself require to be periodically sent to a third party for calibration?  It is not clear to me.  In the past I have received a finding for not doing so.  As I read the standard it is not clear.  Can you provide exactly the clause and reference statement that would indicate and clarify its meaning.

Response:

Your question leads me to believe there was a valid reason for the finding you received. Calibration of a Karl Fischer Electrometric Titration unit is more of a validation and adjustment. That is, in one common practice, you use sodium tartrate dehydrate in a very fine powder form, along with other substances and follow all the steps of calibration.  However, (this is why sending your unit to a third party becomes necessary), you cannot be certain your unit is reading accurately if it hasn’t had a certified calibration by a third party. Example: Is the water equivalent (WE) of the titrant (Karl Fischer reagent or titrating solution) based on accurate calculations?

If you have a known standard which is traceable to national standards which you can use as a comparator, you might be able to set your recalibration periods fairly far apart. This would of course save you money. Nonetheless, unless you can show traceability of your Karl Fischer system, you are not compliant with the standard.

That was a good question and I hope this will help.

Bud Salsbury, CQT, CQI

For more on this topic, please visit ASQ’s website.

Measurement System Analysis

ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories

Question:

Is there ever an exception to the rule about needing full Measurement System Analysis for any instrument placed in the Evaluation / Measurement Technique column on the Control Plan?  If an instrument is listed on the control plan, does it HAVE to have GRRs done, in addition to having to prove stability?  Please base off of ISO 9001 and TS 16949 requirements, and if there is a difference between them for this requirement.   

Answer:

Thank you for this interesting question. Clause 7.6 of ISO 9001: 2008 makes most of this fairly clear. Any monitoring and measuring equipment used to verify conformity of product must “be calibrated or verified, or both, at specified intervals, or prior to use. . .” Notice I made ‘at specified intervals’ bold. This is just to bring to light the importance of calibration cycles. You/your organization can determine what those cycles will be based on the stability of the measuring tool, frequency of use, working conditions, etc. For example, if you were using a micrometer to check close tolerance parts and, you found it a good process to measure the parts frequently, this would be a contributing factor to the decision process. Then, if the working conditions included a lot of cutting fluids or perhaps a good deal of metal dust, another factor is added to the decision process. What I am driving at is this; once you have determined that the product conformity which you are checking is good and/or consistent and that your sample frequency is satisfactory, you would have no definite requirement for GRR’s on the measuring equipment. The calibrations and or verifications you do must be with equipment which is traceable to international or national measurement standards. If you use working standards as gages to check measuring equipment throughout production and those standards are traceable, then you are doing fine. The processes you use to verify the tools and any in-process measuring practices should be documented in Work Instructions or even with the use of photographs or flow charts.

In the second part of your question, you ask if there is a difference between 9001 and TS 16949. I reference section 7.6.1 of TS 16949. Here it is put straight forward:

7.6.1  Measurement System Analysis 

Conduct statistical studies to analyze variation present in the results of each type of MMD that is referenced in the Control Plan.

Use analytical methods & acceptance criteria that: 

Conform to methods and criteria in customer reference (MSA) manuals Or use other methods, if approved by the customer 

This is an automotive sector specific QMS standard. Herein it is necessary to consider safety and liability in everything you do. So, Gage R&R’s are a common practice. Nonetheless, the necessity for these is dictated by individual processes. Some may need them, some may not.

So, if an instrument is listed on YOUR control plan, GRR’s will become a requirement based on all the criteria I’ve noted above. A gage which has proven stability is most often safe from that requirement under 9001 but TS16949 has more extensive requirements.

Bud Salsbury, CQT, CQI

For more about this topic, please visit ASQ’s website.

AS9100C

Airplane, aerospace, AS9100

Question:

Question: AS9100C, which is an expansion of the ISO 9001:2008, states that a “process” based system is being promoted as is shown in 0.2 of the Introduction.  Why are 3rd party auditors being required to use the AS9101 Quality Management Systems Audit Requirements for Aviation, Space and Defense Organizations checklists for their audits?  These check lists are not “process” based and go back to the old procedure systems of the 1994 standard.

Each of our core processes consists of a flow chart of the process, process turtle and PEAR.  If you were doing a true process audit you would take these documents and perform the audit and not limit the auditor to being “boxed in” by a check list.  If the QMS has been developed correctly the process approach audit will allow you to cross other processes when being performed.

Response:

Thanks for the question.  The IAQG AS9101 team does firmly believe in promoting the process approach which you will see reflected with the next AS9101 revision.  I agree that auditors should follow the process while performing all auditing (including 3rd party audits), yet it is also important to ensure that all the AS9100 requirements are satisfied.  That is why AS9100 auditors are trained to audit the process and then complete the Objective Evidence Record to ensure all AS9100 requirements are fulfilled.

Thanks,
Buddy Cressionnie
Americas 9100 Lead

For more on this topic, please visit ASQ’s website.

Use of Correction Fluid to Modify ISO 9001 QMS Documents

ISO documentation practices, requirements

Q: During a recent audit, I discovered that my supplier was using correction fluid and scrubbing out the training records of its employees with no control over the documents. I said that would be a major finding, but they state that there is nothing in ISO/ANSI/ASQ 9001:2008 Quality management systems–Requirements specifically telling them that they can’t correct records on the fly without any control.  Can you clarify this practice for me? I can’t find anything definitive in the standard.

A: This is an interesting question. Sometimes, people complicate standards rather than recognize them for the friendly guides they can be. It is true, as written in clause 6.2.2 of ISO 9001:2008,  that records for education, training, skills and experience need to be maintained per clause 4.2.2. However, the standard does not designate a specific process for this.

Clause 4.2.4 expresses a requirement to establish a documented procedure, and also states that the records should be legible. While the practice of using correction fluid or scrubbing out training records is probably not the best and most professional way of handling things, it’s not a cause for a finding of nonconformance.

Records which have a direct affect on customer products would definitely need better controls. However, I think in this case, you might find it wise to work with the supplier to find a better way of recording employee training. The records must remain legible, readily identifiable and retrievable. If that is what they are doing and product quality is not affected, there should be no major finding. A recommendation for continual improvement would be appropriate.

I hope this helps.

Bud Salsbury
ASQ Senior Member, CQT, CQI

Can We Require ISO 9001 Certification?

Suppliers, supplier management

Q: My company has bought another company in Canada and we are outsourcing to them. They are not certified to ISO/ANSI/ASQ 9001:2008 Quality management systems–Requirements.  Do we have the legal right to require them to get certified since we are?

A: Thank you for contacting the ASQ Ask the Experts Program.  With regard to your question, there is no requirement in ISO 9001 that requires any organization or their suppliers to be certified by a third-party. Certification is only needed if it’s required by a customer contract/purchase order, or if an organization has opted to be ISO 9001 certified.

However, as an ISO 9001 certified organization, your quality management system must include controls to maintain control over outsourced processes. This requirement is stated in clause 4.1. The control over outsourced processes may include all or any of the following:

1.    Use of an approved suppliers list (see clause 7.4.1)

2.    An onsite supplier quality audit (see clause 7.4.3)

3.    Review and approval of equipment, processes, procedures, methods, and personnel qualifications for processes that require validation such as welding, nondestructive testing, heat treatment or others (see clause 7.5.2).

In summary, ISO 9001 certification is a management decision and not a requirement.  Organizations that follow the ISO 9001 requirements and have outsourced processes should have controls in place to manage those processes.

I hope this helps.

Bill Aston
ASQ Senior Member
Managing Director of Aston Technical Consulting Services
Kingwood, TX
www.astontechconsult.com

For more on this topic, please visit ASQ’s website.

Is it Legal to Require Certification to an ISO Standard?

Contract, requirement, legal, standard

Q: Can a contract include a requirement stating that the manufacturer of the materials to be installed as part of the job must be ISO 9001 and ISO 14000 listed? My question is in reference to a contract I received that is requiring this.

A: In general, contracts between business entities are enforceable unless they violate laws or are contrary to public policy. Private businesses entering into commercial contracts have a great deal of freedom in establishing contract terms.

One of the common uses of ISO standards is to clearly delineate requirements in commercial contracts.   This can, and often does, include requirements for third-party certification of suppliers to ISO 9001-2008: Quality management systems–Requirements and/or ISO 14001-2004: Environmental management systems – Requirements with guidance for use.

This requirement is usually met by providing a copy of the certificate issued by a third-party certification body (registrar) that lists the name of the organization certified and the scope of the certification.

Based on the information provided along with your question, it appears that the question actually relates to a material specification that was included as part of a request for proposal (RFP) from a governmental entity. Note: the contract has not been included with this post to protect the anonymity of the questioner and the governmental entity.

The authority of governmental contracting officers is more limited.  They must comply with applicable purchasing statutes and regulations.  Whether or not a requirement for certification to ISO 9001 and/or ISO 14001 is permissible would be determined by reviewing these contracting rules.  These rules also often provide mechanisms for contesting the award of a contract if it is believed to be unfair.

There are often opportunities to request clarification of information included in a government-issued RFP. This may be something to consider in this situation since the requirements in this RFP appear to be unclear, such as:

  •  There is no comprehensive “list” of certified companies so there is no mechanism for a manufacturer to be listed.
  • There is no ISO 14000 standard.  There are over 20 different standards in the ISO 14000 family – each with a different number.  I assume the RFP is referring to ISO 14001.
  • It is not clear which of the materials specified in the contract must be manufactured by an organization that is certified to the ISO 9001 and ISO 14001 standards.

(Note: the contract has not been included with this post to protect the anonymity of the questioner and the governmental entity).

I hope this helps.

Thea Dunmire, JD, CIH, CSP
Chair, ASC Z1-Audit Subcommittee
ENLAR Compliance Services, Inc.
Largo, FL
www.enlar.com

For more on this topic, please visit ASQ’s website.

ISO 9001 Electronic Records

Reviewing confidential files, training records, human resources files
Q: I have a few questions about employee training records.  My company is certified to ISO 9001:2008 Quality management systems–Requirements, and we are considering transitioning to electronic records. However, we don’t know what the requirements are from an ISO perspective. Specifically, we want to know:1. Do we need to retain hardcopy originals, or can we just keep the scanned electronic copies?

2. Does a record need to be in each individual’s file, or can there be a spreadsheet, cross reference-type matrix?

3. How long do they need to be retained?

4. Are there different requirements for environmental and safety type training records?

A: Thank you for contacting the ASQ Ask the Experts Program. Responses to your specific inquiries follow:

1.You may retain records in any format or media you desire.  You do not need both hardcopy and electronic.

2. You may use a spreadsheet matrix.

3. Retention times are your determination. Consult with the corporate attorney as to any requirements from the U.S. Equal Employment Opportunity Commission to protect yourself if there is a lawsuit (assuming your organization is located in the United States).

4. Check with the U.S. Occupational Safety and Health Administration (OSHA) and the U.S. Environmental Protection Agency (EPA) regarding requirements for these records.  These are outside the scope of ISO 9001.

George Hummel
Voting member of the U.S. TAG to ISO/TC 176 – Quality Management and Quality Assurance
Managing Partner
Global Certification-USA
www.globalcert-usa.com/
Dayton, OH

For more on this topic, please visit ASQ’s website.

ISO 9001 Certification to Meet Customer Requirements

Training, completed training, competance

Q: My company is a small manufacturer that makes one product that I designed and engineered. We have a contract to produce the part for a much larger company. The larger company wants us to become certified to ISO 9001:2008 Quality management systems — Requirements. The company has sent its auditor/Six Sigma black belt to our plant for the third time and stated that our operators (three employees, myself included) are not trained because the training matrix is not filled out.

The auditor also stated that our work instructions are not adequate, that our process flow charts are not good enough, and that our forms (all five forms we use in-house) are not compliant because they lack a form number printed on them. Is there a clear definition of what is required by ISO on any of these items?

We currently have a 2.5 percent nonconformance rate on our parts. These are identified at our 100 percent inspection points – at three, four, or five. Out of the 2.5 percent nonconformance, the 2 percent are able to be reworked and the 0.5 percent is scrapped.

A: Your question has several layers so I will try to offer what answers I think will help.

To begin with, I have to assume that you have a copy of the ISO 9001 standard. If you do not have a copy, you must get one.

At the same time, it would benefit you to acquire the services of a consultant or you can purchase one of the many books that are available which would help you along the way.

Now, in ISO 9001:2008, clause 6.2.2 states that you “shall” do five things with regard to competence, training and awareness.

In ISO documentation, the word “shall” indicates a requirement.  Basically, you are required to identify (document) the training requirements of those whose work can affect conformity to product requirements. There is nothing in the standard that says you must have a “matrix.”

You must have a record showing the training has been completed and of its effectiveness. You must also verify each employee’s competence in doing his/her job on their own. Competence is important. Keep that in mind.

You mentioned in your inquiry that your customer states your work instructions are not adequate, that the process flow charts are not good enough, and that your forms are not compliant because they lack a form number printed on them.

To begin, the standard requires just six documented procedures.

  • Clause 4.2.3 Control of documents
  • Clause 4.2.4 Control of records
  • Clause 8.2.2 Internal quality audits
  • Clause 8.3 Control of nonconforming product
  • Clause 8.5.2 Corrective action
  • Clause 8.5.3 Preventive action

Your written procedures need to be compliant with the standard they are for. (By the way, Most companies have more than just six documented procedures, as it helps their Quality Management System to operate more efficiently)

As for process flow charts I am thinking you are referring to work instructions. The 9001:2008 standard says that work instructions should be available “as necessary.” If you have work instructions written and they are readily available, the auditor should have no cause for concern there.

In addressing your mention of “flow charts,” in all fairness, I cannot respond completely without actually seeing the flow charts in question.  If you mean the process flow charts which often accompany a documented procedure to show a “map” of the process, then you should read clause 4.1 of the standard. You would find that you are required to show “interactions” of the processes. There are no actual ISO requirements for flow charts, but many companies use that format to show the interactions, often in their quality manual. You would need to determine if flow charts are needed to ensure consistent quality.

Finally, let’s talk about forms. How you control your forms or the format should be mentioned in your document control procedure (4.2.3).

Each type of form would need a title, a revision number or letter, and a revision date.  Having a record of these makes it easy to identify which version of a document you are using and if it is the correct revision.

I know that approaching ISO compliance can seem like a bigger than life challenge at first. However, for every step you take, you will realize that standards are beneficial and not nearly as complicated as they might first appear to be.  As noted above, you might want to consider a consultant and/or acquire some reference material. Your customer’s auditor can become a friendly associate.

As a senior member of ASQ, I salute you for running a business dedicated to quality.

Bud Salsbury
ASQ Senior Member, CQT, CQI

For more on this topic, please visit ASQ’s website.

Establishing and Maintaining a CAPA System

CAPA process, CAPA requestsQ: We have a Corrective Action and Preventative Action (CAPA) system, and we find that CAPAs are almost always completed late — even though we do have an extension request form for CAPAs, and the system sends automated reminders to  employees in advance.

What can we do to resolve this issue and avoid late CAPAs?

A: I will answer this question based on the information provided.

1. Does the CAPA system rank the CAPA based on risk? If not, each CAPA should be ranked either high, medium, or low.

High risks generally mean that the problem behind the CAPA could have a negative affect on the business and put it at risk. For example, in the medical device industry, a high risk CAPA could include a regulation violation, something that can harm a device user or patient, or issues that could result in legal action against the company.

2. Does the CAPA system have a way to involve top management? If not, it should — especially if timely corrective action is not being taken in instances of high risk CAPAs.

3. Does the management review process include a statistical analysis of the time it takes to complete CAPAs?

Often, reports to management include the number of CAPAs greater than 90-days old and greater than 180-days old. In addition to reporting on the number of open CAPAs, also report on the number of CAPAs completed by the due date and the number of CAPAs that are overdue (past the original, assigned completion date).

It is a good idea to also convert these numbers into percentages to make data digestible and to allow for comparison making.

4. Next, discuss with management (if possible) to consider consequences for employees if company problems that result in a CAPAs are not addressed in a timely manner.

With this approach, proceed with caution. You must make certain that the CAPA system is robust. Not every little problem is a CAPA. A good way to weed out the CAPAs from the non-CAPAs is to ask: is this an issue that requires an investigation into the root cause? And, does this problem require corrective action to fix it? If the answers are yes, then it is probably a CAPA.

5. You may want to consider benchmarking how other organizations structure their CAPA system and look to guidance documents for help. The Global Harmonization Task Force published a guidance document help establish CAPA systems. It is for the medical device industry, but it can be applied elsewhere.

Jim Werner
Voting member to the U.S. TAG to ISO TC 176
Medical Device Quality Compliance (MDQC), LLC.
ASQ Senior Member
ASQ CQE, CQA, RABQSA Lead QMS Assessor

For more about this topic, please visit ASQ’s website. 

Rescheduling an ISO 9001 Surveillance Audit

Schedule, calendar, timeline

Q: Our organization had its last external (third party) audit in December 2011 for ISO 9001:2008 — Quality management systems — Requirements. We planned to have our next audit the week of November 26, 2012, but the auditor has become ill and cannot come at that time.

Do we need to have our surveillance audit within one year of the last audit? I am considering rescheduling for the first quarter of 2013.

A: Thank you for contacting ASQ’s Ask the Experts.  With regard to your inquiry, surveillance audits are usually conducted by most registrars on an annual basis.  Your registrar has complete responsibility for ensuring the availability of their audit staff to conduct these audits as they are required.

In the event that no other auditors can be provided by your registrar, it would be their responsibility to ensure the audit is rescheduled to another mutually agreed upon date and, if necessary, extend your organization’s ISO 9001:2008 certification status as appropriate.

Your organization’s ability to maintain to an active QMS certification status should not be dependent upon the availability of the registrar’s auditor.  I recommend that you contact your registrar to confirm the next date for your surveillance audit.

I hope this helps.

Bill Aston
ASQ Senior Member
Managing Director of Aston Technical Consulting Services
Kingwood, TX
www.astontechconsult.com